Constant Air Volume Generation Device / Air Volume Measurement Device Wind Watcher α (WWA)

[Free test available] Devices that "create wind" and "measure wind." They can easily generate an appropriate amount of wind and accurately measure the wind blowing from existing equipment or being drawn in.

■Free testing available If you would like to test whether the airflow of air purifiers, dust collectors, air conditioners, blowers, small cooling fans, etc., is correct, testing can be conducted at our in-house test center. Please contact us for conditions and details. The "Wind Watcher α (WWA)" is a device that can easily generate an appropriate amount of wind and accurately measure the wind blowing from or being sucked into existing equipment. The anemometer incorporates a rectifying grid and adopts the "Air Measure," which has excellent installation characteristics. By selecting an anemometer suitable for the airflow being measured, the reliability of the measurement values is enhanced. 【Features】 ■ Capable of performing dual roles of "creating wind" and "measuring wind" ■ Displays the amount of wind created, measured airflow, air temperature, and air density ■ Operation via a touch panel, with numerical displays of normal airflow and mass flow, as well as trend graph displays ■ Equipped with 3-channel analog output (4-20mA) ■ CSV data can be copied to USB ■ NETIS registration number: KT-240015-A *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

一定風量発生装置/風量測定装置ウィンドウォッチャーα(WWA)

【東京電機大学との測定論文公開中!】3密の1つ密閉空間の確認、換気風量を正確に簡便に計測

ウインドウォッチャーα(WWA)は、空調に欠かせない制気口(吹出し口や吸込み口)や排煙口、更には厨房など様々な場面における換気風量が計測できます。 整流機能を持つ風量計『エアメジャー』を搭載し風量を正確に捉えることができます。また正確に換気風量を測るためには換気口に集風フードをあてがう必要が出てきますが、それにより発生する圧力差をゼロにするように内蔵補助ファンを自動制御することで集風フードによる風量変化を抑えながら測定できます。 【特長】 ■「風を創る」「風を測る」の2役演じることが可能 ■創り出す風の量や測定した風量、空気温度及び空気密度などを表示 ■操作はタッチパネル、ノルマル風量や質量流量などの数値表示および トレンドグラフ表示ができる ■3chのアナログ出力(4-20mA)を備えている ■CSVデータをUSBにコピー可能 ■NETIS登録番号:KT-240015-A ※詳しくはPDF資料をご覧いただくか、お気軽にお問い合わせ下さい。

  • Measurement and Inspection
  • Air compressors, blowers and pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Airflow meter / Part number ME6L-7821K

Inspection, adjustment, and balancing of air conditioning equipment and systems, as well as airflow measurement for complex air outlet shapes such as grills and diffusers.

● Lightweight and easy to handle, allowing for simple airflow measurement tasks to be performed by one person. ● Wide airflow measurement range: 85 to 4,250 m3/h ● Easy-to-read and user-friendly simple design with a full-color LCD No complicated calculations needed. Airflow is displayed immediately after pressing the start button. (Temperature and humidity are displayed simultaneously) ● Capable of determining the flow direction at intake and exhaust points ● Data logging function for up to 3,000 readings ● Measurement data can be saved with individual ID management ● Built-in back pressure compensation function to ensure accuracy at high airflow rates ● Equipped with atmospheric pressure compensation function ● Transparent hood for easy alignment with air conditioning vents The standard hood is made of transparent material, making it easy to align with air conditioning vents. The hood is foldable and does not take up storage space. ● Five types of optional hoods to choose from based on application A standard hood measuring 610×610mm is included. Additionally, five other hoods of different sizes are available (sold separately). ● Stand compatible with high ceilings (optional) A stand that can be extended from 1.2 to 2.5m is available (sold separately).

  • Anemometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Duct-mounted air flow detector duct meter for general air / chemical resistance

24 hours a day, 365 days a year, wind flow measurement is always possible! Ideal for monitoring air volume in industrial air conditioning and equipment! Wind flow is monitored via a display, and wind flow values can be output in analog form.

The duct meter "DMS-N1A" is a wind speed and temperature detection system that installs wind speed and temperature probes in factory supply and exhaust ducts and equipment, allowing for monitoring of airflow through an indicator and enabling analog output of airflow values. Traditionally, operators would visit measurement points to measure and record wind speeds at various locations, but the "DMS-N1A" can continuously measure airflow 24 hours a day, 365 days a year. There are also wind speed and temperature probes with chemical resistance that can monitor exhaust airflow in semiconductor factories, pharmaceutical factories, and research facilities for extended periods. 【Features】 ■ Wind speed detection range: 0.1 m/s to 15 m/s; temperature range for wind speed detection: -10°C to 50°C ■ Easy to set airflow scale, cross-sectional area, units, etc.! ■ Wind speed and temperature sensors are compatible and easy to maintain. *For more details, please download the catalog or feel free to contact us.

  • Anemometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Solving the issues of conventional air flow measurement methods 【Free booklet】

First! The calibration of the anemometer can be done accurately!

We are currently offering a booklet that presents the issues with traditional measurement methods and solutions to those problems. Airflow measurement is essential for CO2 reduction, product quality stability, and maintaining a safe working environment! ● Are you indiscriminately increasing airflow or exhaust volume? ● Is there an airflow meter in the exhaust duct of your drying oven that allows for accurate numerical management? ● Do you think that maintaining positive pressure indoors alone will provide sufficient ventilation? ◆ If any of the above apply to you, please feel free to contact us. ◆ If you would like to receive the booklet, please request it through the [Contact Us] section. *You can view part of the booklet from the [Catalog Download].

  • Surveying
  • Anemometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Constant Air Volume Generation Device / Air Volume Measurement Device Wind Watcher α (WWA)

[Free Test Available] Simple efficiency evaluation of heat exchangers and determination of appropriate air volume for control panels.

■Free testing available If you would like to test whether the airflow of air purifiers, dust collectors, air conditioners, blowers, small cooling fans, etc., is functioning correctly, testing can be conducted at our in-house test center. Please contact us for conditions and details. The Wind Watcher α (WWA) can accurately measure airflow and pressure while suppressing disturbances through automatic control, allowing for visualization of appropriate airflow. The Wind Watcher can continuously flow a constant airflow through small test specimens, enabling the investigation of heat transfer with a simple device. It is also possible to determine the appropriate airflow for cooling, which is crucial for control panels and large medical equipment's exhaust heat. Airflow is accurately captured using the airflow meter 'Air Measure,' which has a rectifying function. 【Features】 ■ Capable of performing dual roles of "creating wind" and "measuring wind" ■ Displays the amount of wind created, measured airflow, air temperature, and air density ■ Operation via touch panel, with numerical displays for normal airflow and mass flow, as well as trend graph displays ■ Equipped with 3-channel analog output (4-20mA) ■ CSV data can be copied to USB ■ NETIS registration number: KT-240015-A *For more details, please refer to the PDF document.

  • Measurement and Inspection
  • Air compressors, blowers and pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration